INSTALLATION OF TOP WALL-MOUNTING BRACKET FOR
SENTINEL ENLARGER

- Secure a suitable mounting board to your wall. A
two-foot-long piece of 2x8 lumber secured to two studs
is recommended. In the case of a floor-standing Sentinel,
however, a lighter-duty arrangement will suffice.
- Attach the two pieces of the Wall-Mounting Bracket
together. The Wall-Mount Box attaches to the Plate
via the two large studs on the Plate. Place the Box
onto the plate, positioning the two slots in the Box
over the large studs. Observe the correct orientation
when doing this: No part of the Box should over-hang
any edge of the plate when the two are assembled correctly.
Use the two washers and nus provided to secure the
Box and Plate together. At this time only make these
nuts only finger tight.
- With the Sentinel in position near the wall, place
the assembled bracket over the top of the column,
roughly aligning the slotted holes in each side of
the box with the holes in the Sentinel's column. Do
this in order to determine the correct position at
which to secure the plate to the piece of wood in
the wall.
Once the proper position is determined, such that
the slotted holes in the sides of the Box will align
with the holes in the Sentinel's column, secure the
Wall Mounting Assembly to the wood using six large
wood screws or lag bolts.
- Move the Sentinel into it's final position on the
floor of the darkroom. Make fine adjustments to it's
position, so that the Holes in the box are in position
over the holes on the Sentinel's column. Insert one
screw (provided) into the hole on each side of the
Column, securing the Wall Mounting Bracket to the
Sentinel's column. Tighten these screws once final
position is achieved.
The top of the Sentinel's column is now secured, adding
rigidity to the floor-standing machine.
|