Technical Support Document 029 - 5/97


Description of Starlite's "CODE#2" Error

This is an out of range error reading the RMS voltage signal while the lamps are being run at a fixed, known, low duty cycle. The lamps should be around 7 volts during this test for the 110 version or a little higher (11volts) for the 220 version. If the computer reads the RMS voltage and it is below 4.0 volts or higher than 130 volts a CODE 2 error will appear.

Possible causes are due to the lamp drive not working properly or the RMS voltage not being read properly. The first thing to check is if the lamps are turning on, if so then the problem lies in reading the RMS voltage.

It is recommended that you run the "Manual Control Test" diagnostic routine. For more information, please contact ZBE, Inc. at the numbers listed below.


 